MMPs sensitive detection and activity quantitation
Our SensoLyte® 520 Generic MMP Activity Kit allows monitoring the activity of a set of matrix metalloproteinases from biological samples in a highly sensitive assay.
Sensitive
- Proprietary FRET substrates with unique properties: QXL® 520 and
5-FAM provide the best combination for a detection in the green channel; orange and blue alternatives are available - Less interference from biological sample autofluorescence
- Super-sensitivity with a detection level as low as subnanogram of active MMPs
Convenient
- Detection of MMP-1, 2, 3, 7, 8, 9, 12, 13 and 14
- 96-well plate format
- Homogenous format works for High throughput Screening (HTS)
Trusted
- 15 years of expertise in Assays, Peptides and Dyes development
- AnaSpec (Eurogentec’s US subsidiary) Quality
- Citations in peer-reviewed journals
How to detect MMP activity?
Our SensoLyte® MMP Fluorimetric assays are the most convenient way to detect MMP family members in a 96-well format assay.
Our FRET-based MMP activity assay kits allow the measurement of MMP activity as well as the high throughput screening of MMPs’ inducers and inhibitors with a minimal hands-on time.
Generic MMP Fluorimetric Assay Kits | ||||
---|---|---|---|---|
Product | Detection Method | Dye /Quencher (Abs/Em) in nm | Cat# | |
SensoLyte® 520 Generic MMP Activity Kit Targets: MMP-1; MMP-2; MMP-3; MMP-7; MMP-8; MMP-9; MMP-1; MMP-13; MMP-14 |
Fluorimetric - FRET Super-sensitive |
•
5-FAM/QXL520™ (490/520) |
AS-71158 | Order now |
SensoLyte® 570 Generic MMP Assay Kit Targets: MMP-1; MMP-2; MMP-3; MMP-7; MMP-8; MMP-9; MMP-1; MMP-13; MMP-14 |
Fluorimetric - FRET |
•
5-TAMRA/QXL™ 570 (540/575) |
AS-72101 | Order now |
SensoLyte® 390 Generic MMP Activity Kit Targets: MMP-1; MMP-2; MMP-3; MMP-7; MMP-8; MMP-9; MMP-1; MMP-13; MMP-14 |
Fluorimetric - FRET |
•
Mca/Dnp (330/390) |
AS-72202 | Order now |
How does a FRET-based detection kit work?
A FRET peptide is used as the MMP substrate.
In intact peptide substrate, the fluorescence of the fluorophore is quenched by a QXL™ proprietary quencher.
In the presence of MMPs in the tested sample, the FRET peptide substrate is cleaved. The fluorescence of the fluorophore is released and can be monitored.
Why use FRET-based detection kits?
- MMPs fast and sensitive detection in biological samples
- MMPs activity measurement
- High Throughput screening of MMPs’ inducers and inhibitors
- Drug discovery to treat tumors, rheumatoid arthritis and other diseases.