Assay-kits

SensoLyte® 520 FRET Sirt1 Assay Kit Fluorimetric - 1 kit

566.00
Check your price
  • Cat.Number : AS-72155
  • Availability :
    In stock
  • Shipping conditions : Ice delivery fees must be applied

Alternative choices

Quantity

Histone deacetylase (HDAC) enzymes act as transcriptional repressors of genes through the deacetylation of lysine residues on histone proteins. Sirtuins (SIRTs) are a unique class of deacetylases (class III HDACs) that require NAD as a cofactor. Sirtuin 1 (SIRT1) is involved in regulation of tumor suppressor p53 and inhibition of apoptosis. It also represents a target for treatment of age-related diseases and type II diabetes.
The SensoLyte® 520 FRET SIRT1 Assay Kit provides a convenient, two-step homogeneous procedure for measuring sirtuin 1 activity using a FRET substrate. In the first step, an acetylated substrate is incubated with SIRT1 containing samples. Deacetylation of substrate first sensitizes it, so that, in the second step mixing with the SIRT developer generates a fluorophore, which can then be detected at Ex/Em= 490/520 nm. This kit can be used for high throughput screening of SIRT1 inhibitors/activators. The long wavelength fluorescence of FRET substrate is less interfered by the autofluorescence of cell components and test compounds. The nuclear extract HDAC (containing HDACs 1 and 2) does not deacetylate FRET sirtuin substrate. Assays are performed in a standard 96-well format.

Specifications

Packaging
Kits components
  • Component A: SIRT1 520 FRET substrate: 1 mM, 50 µL Component B: Deacetylated FRET reference substrate, Ex/Em=490 nm/520 nm after cleavage: 1 mM, 20 µL Component C: SIRT1, Human Recombinant: 0.025 mg/mL, 400 µL Component D: Assay Buffer: 20 mL Component E: NAD+: 20 mM, 100 µL Component F: Nicotinamide (Sirtuin Inhibitor): 30 mM, 0.5 mL Component G: SIRT1 Developer (10X): 0.5 mL
Chemistry
UniProt number
  • Q96EB6
Properties
Absorbance (nm)
  • 490
Emission (nm)
  • 520
Storage & stability
Storage Conditions
  • Store component C at -80°C. Store all other components at -20°C. Component D can be stored at room temperature for convenience. Protect components A and B from light and moisture.
Activity
Application
Biomarker Target
Detection Method
Detection Limit
  • 13 ng/ml
Research Area
Sub-category Research Area
Usage
  • Research use
Source
Host
Codes
Code Nacres
  • NA.32

You may also be interested in the following product(s)

Vial of Human Sirtuin 1, recombinant protein

Human Sirtuin 1, recombinant

Cat.Number : AS-72212
135.00 Excl. Tax
Image of a kit SensoLyte 520 FRET SIRT2 Assay Kit Fluorimetric

SensoLyte® 520 FRET SIRT2 Assay Kit Fluorimetric - 1 kit

Cat.Number : AS-72189
611.00 Excl. Tax
Image of a kit SensoLyte Green Sirt1 Assay Kit Fluorimetric

SensoLyte® Green Sirt1 Assay Kit Fluorimetric - 1 kit

Cat.Number : AS-72156
582.00 Excl. Tax